Demonstration system record. All values are illustrative and do not describe a real product.
One record, many details
This is the single system record for Example LGS Panelised Wall System. Every detail sheet drawn from this system links back to this one record rather than duplicating its data, and this record lists every one of those sheets below - the relationship works in both directions, from the sheet to the system and from the system to its sheets.
Identity
| System family | Light gauge steel panelised, open panel | Documented |
| Primary structure | Cold formed steel C sections, 70 to 150mm | Documented |
| Intended applications | Housing and MDU to 6 storeys | Declared |
Performance
| External wall U value | 0.18 W/m2K in standard buildup | Verified |
| Fire resistance, loadbearing wall | REI 60 tested to BS EN 1365-1 | Documented |
| Acoustic, party wall | DnT,w + Ctr 52 dB site measured | Verified |
| Airtightness achieved | 1.9 m3/h.m2 at 50Pa, mean of 24 plots | Verified |
Certification
| System certification | BOPAS accredited, current | Documented |
| Warranty acceptance | NHBC accepted with conditions | Documented |
| Declared design life | 60 years structural | Declared |
Design integration
| Standard details | 12 details in the ICK library, Base, Wall, Floor, Roof sets | Documented |
| BIM provision | IFC and native families, LOD 350 | Declared |
| Design freeze point | Stage 4 sign off, 12 weeks before production | Declared |
Durability and maintenance
| Maintenance manual | Structured schedule held, BOPAS D+M format | Documented |
| Key component service lives | Membranes 30 years, sealants 20 years, declared | Declared |
| Inspection regime | 5 yearly external fabric review recommended | Declared |
Delivery and commercial
| Capacity | 1,200 panels per week, single shift | Declared |
| Lead time | 14 weeks from design freeze | Declared |
| Indicative cost band | Band C of E, basis and date recorded on live records | Declared |
Linked details in the library
These 12 sheets in the ICK Detail Library are drawn from this system. Open them in the Detail Library.
| ICK-B-011 | End Wall Base Detail, Brick Slip & Screed | Base & Ground Floor |
| ICK-B-012 | Ground Floor / Pad Foundation Details | Base & Ground Floor |
| ICK-W-001 | Window Cill Detail, Render Finish | External Wall |
| ICK-B-001 | External Wall DPC Detail | Base & Ground Floor |
| ICK-F-001 | First Floor Wall Joint | Intermediate Floor |
| ICK-F-002 | First Floor Party Wall Detail | Intermediate Floor |
| ICK-F-003 | PCC Mid Floor Connections | Intermediate Floor |
| ICK-R-001 | Typical Parapet Detail | Roof & Parapet |
| ICK-R-002 | Roof Eaves Detail | Roof & Parapet |
| ICK-R-004 | Roof Cassette Detail | Roof & Parapet |
| ICK-W-003 | Typical Wall Construction | External Wall |
| ICK-W-005 | Window Sill Detail, 140mm Sill | External Wall |
Digital escrow
This system holds a lodged escrow deposit: fire test reports, structural calculations, manufacturing specifications, BIM models and O+M documentation. Release triggers include insolvency, ceasing production or failure to support. Beneficiaries are named clients, contractors and warranty providers. Deposit completeness verification is carried out under the ICK methodology.